Stator Winding Inter-Turn Short: How We Found One and How the Surge Test Catches Them
We checked the two obvious suspects first: the controller and encoder pairing, then the shaft and bearings. Both came back clean. The fault was inside the stator — a few turns in one phase had lost the insulation between them and were acting as one thick turn.
That is an inter-turn short, and it is the failure a multimeter, a megger and a hipot test can all miss. This article walks through how we found it, why the usual tests miss it, and how the surge comparison test works: the stator as a resistor, inductor and capacitor, the three stages of one pulse, how to choose peak voltage and wavefront time, and how to read pass or fail.